top
Search terms
Results 1 - 10 of 11 - ordered by :
Pages: 1 2
Ehjournal

First-in-man transapical mitral valve replacement using the Direct Flow Medical® aortic valve prosthesis Echocardiography revealed severe mitral valve (MV) stenosis with an MV area of 0.6 cm2 ...

European Heart Journal, Mellert, Fritz, Sinning, Jan-Malte, Werner, Nikos, Welz, Armin, Grube, Eberhard, Nickenig, Georg, Hammerstingl, Christoph

Date : 14/08/2015 Item size : 98507 bytes
Ehjournal

Detailed information on the Carillon-device and the MitraClip-technique have been published earlier. 3D TEE confirmed Carillon-device placement on the posterior circumference of the MV annulus with ...

European Heart Journal, Schueler, Robert, Werner, Nikos, Nickenig, Georg, Hammerstingl, Christoph

Date : 14/07/2016
Ehjournal

A 80-year-old male presented with New York Heart Association (NYHA) IV functional class and peripheral oedema 6 years after mitral valve (MV) surgery comprising restrictive annuloplasty (St Jude ...

European Heart Journal, Hammerstingl, Christoph, Sinning, Jan Malte, Schiller, Wolfgang, Buchbinder, Maurice, Nickenig, Georg

Date : 14/06/2013 Item size : 89774 bytes
Ehjournal

Abstract Aims Cardioband system is a direct annuloplasty adjustable device that is implanted in the beating heart on the posterior annulus under fluoroscopic and transoesophageal echocardiographic ...

European Heart Journal, Maisano, Francesco, Taramasso, Maurizio, Nickenig, Georg, Hammerstingl, Christoph, Vahanian, Alec, Messika-Zeitoun, David, Baldus, Stephan, Huntgeburth, Michael, Alfieri, ...

Date : 07/03/2016
Ehjournal

Owing to severe co-morbidities (STS score 13.8%) and a history of surgical aortic valve replacement in 2008, the Heart Team decided to perform transcatheter MV replacement (TMVR) via transapical ...

European Heart Journal, Sinning, Jan-Malte, Mellert, Fritz, Schiller, Wolfgang, Welz, Armin, Nickenig, Georg, Hammerstingl, Christoph

Date : 01/09/2013 Item size : 107848 bytes
Ehjournal

Owing to severe co-morbidities (STS score 13.8%) and a history of surgical aortic valve replacement in 2008, the Heart Team decided to perform transcatheter MV replacement (TMVR) via transapical ...

European Heart Journal, Sinning, Jan-Malte, Mellert, Fritz, Schiller, Wolfgang, Welz, Armin, Nickenig, Georg, Hammerstingl, Christoph

Date : 01/09/2013 Item size : 119199 bytes
Ehjournal

Open-heart surgery was declined because of relevant co-morbidities (Euro-SCORE-II: 24%; STS-Score: 13.9%); therefore, a combined interventional approach was chosen. [...]a guide wire was positioned ...

European Heart Journal, Hammerstingl, Christoph, Nickenig, Georg, Endlich, Matthias, Mellert, Fritz, Schiller, Wolfgang

Date : 01/08/2012
Ehjournal

A 80-year-old male presented with New York Heart Association (NYHA) IV functional class and peripheral oedema 6 years after mitral valve (MV) surgery comprising restrictive annuloplasty (St Jude ...

European Heart Journal, Hammerstingl, Christoph, Sinning, Jan Malte, Schiller, Wolfgang, Buchbinder, Maurice, Nickenig, Georg

Date : 14/06/2013
Ehjournal

Detailed information on the Carillon-device and the MitraClip-technique have been published earlier. 3D TEE confirmed Carillon-device placement on the posterior circumference of the MV annulus with ...

European Heart Journal, Schueler, Robert, Werner, Nikos, Nickenig, Georg, Hammerstingl, Christoph

Date : 14/07/2016 Item size : 114591 bytes
Ehjournal

First-in-man transapical mitral valve replacement using the Direct Flow Medical® aortic valve prosthesis Due to high surgical risk (STS score 6.8%) with a history of surgical aortic valve ...

European Heart Journal, Mellert, Fritz, Sinning, Jan-Malte, Werner, Nikos, Welz, Armin, Grube, Eberhard, Nickenig, Georg, Hammerstingl, Christoph

Date : 14/08/2015 Item size : 122279 bytes