Pages: 1 2 3 4 5 ... 5
Heart

Study of the diagnostic value of aortic valve area planimetry using multiplane TOE, compared with catheterisation and the continuity equation, both being considered as criterion standards. PATIENTS: ...

Heart, Research Article, Y. Bernard, N. Meneveau, A. Vuillemenot, D. Magnin, T. Anguenot, F. Schiele, J. P. Bassand

Date : 01/07/1997
Heart

RESULTS--Differences in individual patients' measurements of aortic valve area by the three Doppler techniques varied by up to 0.56 cm2 compared with values obtained by heart ...

British Heart Journal, Research Article, J. L. Fischer, T. Haberer, D. Dickson, L. Henselmann

Date : 01/03/1995
Heart

To investigate the effects of transvalvar flow rate on aortic valve resistance and valve area after percutaneous transvenous balloon dilatation of the mitral valve in a homogeneous group of patients ...

Heart, Research Article, T. M. Lee, S. F. Su, M. F. Chen, C. S. Liau, Y. T. Lee

Date : 01/12/1996
Heart

[...]symptoms can be revealed by treadmill exercise in a large proportion of apparently asymptomatic patients.1 Patients may limit exercise to avoid symptoms or may fail to recognise the presence of ...

Heart, Education in Heart, John Chambers

Date : 01/04/2006
Heart

Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques Dr U Sechtem Department of Cardiology, Robert Bosch Medical ...

Heart, Cardiovascular medicine, C Kupfahl, M Honold, G Meinhardt, H Vogelsberg, A Wagner, H Mahrholdt, U Sechtem

Date : 01/08/2004
Eurointervention

Left ventricular outflow tract (LVOT) and ascending aorta (AA) cross-sectional area was determined in two-dimensional transthoracic echocardiography (2DTTE), 2D transesophageal echocardiography ...

Date : 14/09/2015 Item size : 32920 bytes
Ehjcardioimaging

Introduction Transcatheter aortic valve implantation (TAVI) techniques have emerged as an alternative treatment for patients with severe aortic stenosis and high surgical risk.1 Since the ...

European Heart Journal - Cardiovascular Imaging, Clinical/Original Paper, Alexandra Gonçalves, Pedro Marcos-Alberca, Carlos Almeria, Gisela Feltes, Enrique Rodríguez, Rosa Ana ...

Date : 01/10/2011 Item size : 284543 bytes
Ehjcardioimaging

Abstract Aims Echocardiographic assessment of patients with mitral valve stenosis (MS) requires a detailed evaluation of mitral valve anatomy, mitral valve area (MVA), and pressure gradient and ...

European Heart Journal - Cardiovascular Imaging, ORIGINAL ARTICLES, Funda Helvacioglu, Ozlem Yildirimturk, Cihan Duran, Selen Yurdakul, Yelda Tayyareci, Onur Levent Ulusoy, Saide Aytekin

Date : 01/02/2014 Item size : 228918 bytes
Ehjcardioimaging

Study cohort included 166 males with age 70 ± 9 years, of which 72 (43%) had D. Baseline CAS was mild in 66 subjects, moderate in 75, and severe in 25. DiabetesAtherosclerosisAortic stenosis ...

European Heart Journal - Cardiovascular Imaging, Clinical/Original Paper, Masoor Kamalesh, Charlotte Ng, Hicham El Masry, George Eckert, Stephen Sawada

Date : 01/08/2009 Item size : 178814 bytes
Ehjcardioimaging

Usefulness of the right parasternal view and non-imaging continuous-wave Doppler transducer for the evaluation of the severity of aortic stenosis in the modern area Abstract Aims Evaluation of the ...

European Heart Journal - Cardiovascular Imaging, Clinical/Original Paper, Caroline Cueff de Monchy, Laurent Lepage, Isabelle Boutron, Mohamed Leye, Delphine Detaint, Fabien Hyafil, Eric Brochet, ...