Eurointervention

METHODS AND RESULTS Retrospective analysis of extent and pattern of device landing zone calcification was performed in 386 consecutive patients with sufficient CT-quality. Retrospective assessment ...

Date : 06/05/2016 Item size : 31386 bytes
Eurointervention

Non-invasive imaging is essential for evaluating patient eligibility, planning of vascular access and sizing, which is selecting a prosthesis size that matches the patient anatomy.

Date : 20/04/2012 Item size : 31991 bytes
Eurointervention

Department of Radiology, Erasmus MC, Rotterdam, The Netherlands Aims: Whereas transthoracic echocardiography is the modality of choice for the diagnosis of severe aortic stenosis and cine-fluoroscopy ...

Date : 30/09/2010 Item size : 34367 bytes
Eurointervention

How would I treat? THE INVITED EXPERTS OPINION Jan-Malte Sinning*, MD, PhD; Eberhard Grube, MD, PhD Heart Center Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany ...

Date : 22/04/2014 Item size : 38831 bytes
Eurointervention

THE MEDTRONIC ENGAGER VALVE PROSTHESIS The EngagerTM aortic valve bioprosthesis (Medtronic, Inc., Minneapolis, MN, USA). consists of a self-expanding nitinol frame and a biological heart valve. The ...

Date : 15/09/2013 Item size : 41787 bytes
Eurointervention

Transthoracic echocardiography showed a preserved left ventricular ejection fraction (LVEF) of 60%, moderate left ventricular hypertrophy with diastolic dysfunction grade I and mild pulmonary ...

Date : 20/07/2015 Item size : 43424 bytes
Eurointervention

Aims: Low coronary take-off and small sinus of Valsalva, which is frequently observed in patients with small body size, increase the risk of coronary occlusion during transcatheter aortic valve ...

Date : 28/09/2014 Item size : 32269 bytes
Eurointervention

EuroIntervention Anatomic characteristics of the aortic root in elderly patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation EuroIntervention Anatomic ...

Date : 25/05/2010 Item size : 30641 bytes
Eurointervention

Samim M., Agostoni P., Nijhoff F., Doevendans P., Stella P. Aims: Optimal positioning of the transcatheter aortic prosthesis is paramount to procedural success of transcatheter aortic valve ...

Date : 21/05/2013 Item size : 32615 bytes
Eurointervention

PAR was predominantly seen in the area of the aorto-mitral fibrous continuity and in the area which contains the aspect of the largest diameter of the aortic annulus on the inside curve of the ...

Date : 17/05/2011 Item size : 33784 bytes