top
Search terms
Results 1 - 10 of 35 - ordered by :
Pages: 1 2 3 4
Eurointervention

METHODS AND RESULTS Retrospective analysis of extent and pattern of device landing zone calcification was performed in 386 consecutive patients with sufficient CT-quality. Retrospective assessment ...

Date : 06/05/2016 Item size : 31386 bytes
Eurointervention

CTU Bern, Department of Clinical Research, and Institute of Social and Preventive Medicine (ISPM), University of Bern, Bern, Switzerland Aims: We sought to analyse local distribution of aortic ...

Date : 20/10/2014 Item size : 35072 bytes
Eurointervention

Anatomical predictors of this complication are: annulus dimensions and shape, calcium distribution, angle between the ascending aorta axis and the left ventricular outflow tract ...

Date : 30/09/2012 Item size : 31562 bytes
Eurointervention

Left ventricular outflow tract (LVOT) and ascending aorta (AA) cross-sectional area was determined in two-dimensional transthoracic echocardiography (2DTTE), 2D transesophageal echocardiography ...

Date : 14/09/2015 Item size : 32920 bytes
Eurointervention

EuroIntervention Calcium distribution pattern of the aortic valves as a risk factor for the occurrence of conduction abnormalities after transcatheter aortic valve implantation University Heart ...

Date : 14/09/2015 Item size : 33875 bytes
Eurointervention

Recently, transcatheter mitral valve-in-ring procedures have been shown to be a feasible alternative in selected high-risk patients and are associated with good short-term outcomes. [...]there are ...

Date : 14/09/2015 Item size : 33936 bytes
Eurointervention

The procedural success rates were 97.5% for TS and 100% for Accutrak.There were no significant differences in baseline ECG characteristics between patients who use the traditional system compared ...

Date : 17/05/2011 Item size : 33890 bytes
Eurointervention

EuroIntervention Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve system in patients with aortic stenosis CA were assessed by 2 ...

Date : 17/05/2011 Item size : 34476 bytes
Ehjcardioimaging

Following the uneventful deployment under three-dimensional transoesophageal echocardiographic (3D-TEE; Philips Epiq 7, Philips Medical System, Andover, MA, USA) guidance, an angiographically ...

Eur Heart J Cardiovasc Imaging, IMAGE FOCUS, Frédéric Poulin, Van Hoai Viet Le, Florent Chevalier, Ismail El-Hamamsy, Philippe Généreux

Date : 01/11/2014 Item size : 125259 bytes
Ehjcardioimaging

Introduction Prosthesispatient mismatch (PPM) is observed after surgical aortic valve replacement (AVR) and has been shown to be associated with more cardiac events and decreased long-term survival.1 ...

Eur Heart J Cardiovasc Imaging, ORIGINAL ARTICLES, Hiroto Utsunomiya, Hirotsugu Mihara, Yuji Itabashi, Sayuki Kobayashi, Robert J. Siegel, Tarun Chakravarty, Hasan Jilaihawi, Raj R. Makkar, Takahiro ...

Date : 01/01/2017 Item size : 265834 bytes